Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
1.
Medicine (Baltimore) ; 100(33): e26988, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34414978

RESUMO

ABSTRACT: With the declining use of the pulmonary artery catheter (PAC), transesophageal echocardiography (TEE) has become an appealing alternative to obtain pulmonary artery pressure non-invasively using the simplified Bernoulli equation. The validation of this method in the perioperative setting has been scarce with no clear recommendations about which view is the most accurate to estimate right ventricular systolic pressure (RVSP).Therefore, we performed a prospective, observer-blinded, diagnostic test accuracy study to assess the difference in systolic pulmonary artery pressure (sysPAP) measuring both, invasively sysPAP and estimated RVSP with TEE in 3 different views: the mid-esophageal (ME) 4Chamber, the ME right ventricular (RV) inflow-outflow and the ME modified bicaval view.To show a clinically significant difference of at least 10% in RVSP, we included 40 cardiac surgical patients divided into 3 subgroups: Patients with mild to moderate tricuspid regurgitation (TR) and mean PAP <25 mm Hg, patients with mild to moderate TR and mean PAP≥ 25 mm Hg, and patients with severe TR.For the whole cohort, bias of estimated RVSP compared to measured sysPAP was 5.27 mm Hg, precision was 7.96 mm Hg, limits of agreement were -10.66 to 21.19 mm Hg. The best agreement between the 2 methods was found in patients with severe TR and in the ME RV inflow-outflow and the modified bicaval view. Good Doppler signals were available in 35% and 46% in these views, and in 20% in the ME 4 chamber view.The estimation of the sysPAP by TEE cannot be considered reliable in the clinical perioperative setting. Only measurements that provide a full Doppler envelope show sufficient precision to provide accurate estimations.


Assuntos
Ecocardiografia Transesofagiana/métodos , Hipertensão Arterial Pulmonar/classificação , Pesos e Medidas/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea/fisiologia , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Pesos e Medidas/instrumentação
2.
Pan Afr Med J ; 38: 296, 2021.
Artigo em Francês | MEDLINE | ID: mdl-34178215

RESUMO

The purpose of this study is to assess the role of transesophageal echocardiography at the Dax Hospital Center based on indications, patients´ profile, results, cost-effectiveness and consistency with prescribers´ expectations. We conducted a retrospective, cross-sectional, descriptive and analytical study at the Cardiovascular Laboratory of the Dax Hospital Center from January 2016 to December 2018. The study included 434 exams out of 460 requested. The variables of interest were: demographic profile of the study population, indications, results, cost-effectiveness and consistency with prescribers´ expectations. The average age of patients undergoing the 434 exams included was 64.37 years, male patients accounted for 64.29%, with a sex ratio of 1.8. Stroke assessment (63.59%), the search for infective endocarditis (16.12%) and the assessment of the treatment of intracavitary thrombi (11.75%) were the main indications. Prescribers were mainly neurologists (60.83%). The examination was normal in 58.99% of cases. The pathological results (40,78%) were dominated by thrombi in the auricle (27.65%), altered auricle emptying (9.45%), the presence of foramen oval permeable (5.07%), interatrial septal aneurysm (2.53%) and infective endocarditis (2.76%). The exam was cost-effective in 40.78% of cases and the results were consistent with prescribers´ expectations in 39.86% of cases. Our study transesophageal echocardiography showed that the indications were dominated by stroke assessment. TEE is a cost-effective diagnostic test with a low rate of complications, and whose results are in line with practitioners' expectations.


Assuntos
Ecocardiografia Transesofagiana/estatística & dados numéricos , Endocardite/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Trombose/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Estudos Transversais , Ecocardiografia Transesofagiana/economia , Feminino , Hospitais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
3.
J Am Coll Cardiol ; 78(2): 112-122, 2021 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-33957241

RESUMO

BACKGROUND: The impact of utilization of intraoperative transesophageal echocardiography (TEE) at the time of isolated coronary artery bypass grafting (CABG) on clinical decision making and associated outcomes is not well understood. OBJECTIVES: The purpose of this study was to determine the association of TEE with post-CABG mortality and changes to the operative plan. METHODS: A retrospective cohort study of planned isolated CABG patients from the Society of Thoracic Surgeons Adult Cardiac Surgery Database between January 1, 2011, and June 30, 2019, was performed. The exposure variable of interest was use of intraoperative TEE during CABG compared with no TEE. The primary outcome was operative mortality. The association of TEE with unplanned valve surgery was also assessed. RESULTS: Of 1,255,860 planned isolated CABG procedures across 1218 centers, 676,803 (53.9%) had intraoperative TEE. The percentage of patients receiving intraoperative TEE increased over time from 39.9% in 2011 to 62.1% in 2019 (p trend <0.0001). CABG patients undergoing intraoperative TEE had lower odds of mortality (adjusted odds ratio: 0.95; 95% confidence interval: 0.91 to 0.99; p = 0.025), with heterogeneity across STS risk groups (p interaction = 0.015). TEE was associated with increased odds of unplanned valve procedure in lieu of planned isolated CABG (adjusted odds ratio: 4.98; 95% confidence interval: 3.98 to 6.22; p < 0.0001). CONCLUSIONS: Intraoperative TEE usage during planned isolated CABG is associated with lower operative mortality, particularly in higher-risk patients, as well as greater odds of unplanned valve procedure. These findings support usage of TEE to improve outcomes for isolated CABG for high-risk patients.


Assuntos
Ponte de Artéria Coronária/mortalidade , Ecocardiografia Transesofagiana/estatística & dados numéricos , Idoso , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Estados Unidos/epidemiologia
4.
ABC., imagem cardiovasc ; 34(4): eabc258, 2021. tab, ilus
Artigo em Português | LILACS | ID: biblio-1361250

RESUMO

Introdução: A ecocardiografia é uma ferramenta diagnóstica de crescente utilização na prática clínica, aplicada a diversos cenários médicos. Os cuidados e os processos de manutenção preventiva ou corretiva dos equipamentos são ainda pouco padronizados. O objetivo do presente estudo foi descrever o processo de manutenção atualmente aplicado a equipamentos ecocardiográficos em um laboratório. Descrever o processo inclui a caracterização de danos e aplicações de manutenção preventiva ou corretiva. Métodos: Estudo observacional descritivo e exploratório realizado em centro único. As informações de dados do processo de manutenção de equipamentos ecocardiográficos foram obtidas de arquivos eletrônicos do sistema de gestão de equipamentos de um laboratório de médio porte de um hospital público de nível terciário com características de ensino, no período de 2003 a 2018. Resultados: Foram identificados dez tipos de avarias mais comuns, como dano a programas (23,8%), peças (23,1%) e relacionadas à queda de energia e de acessórios (13,8%). Após a implementação do processo de manutenção preventiva, houve significativa redução dos custos de manutenções (US$ 44.472,10 versus US$ 25.807,59; p= 0,029). Mesmo após a manutenção preventiva, os custos de manutenção corretiva em equipamentos aplicados à ecocardiografia transesofágica (US$ 7.789,17) foram maiores que aqueles a equipamentos aplicados a outras modalidades (US$ 3.184,37 em ecocardiografia transtorácica e US$1.813,00 em estresse). Conclusão: O processo de manutenção de equipamentos ecocardiográficos foi descrito. Danos a equipamentos ecocardiográficos estão relacionados a altos custos, principalmente naqueles aplicados a modalidades especiais, como ecocardiografia transesofágica. As manutenções preventivas reduziram significativamente os custos de manutenção. (AU)


Introduction: Echocardiography is a diagnostic tool that is increasingly used in clinical practice in different medical scenarios; however, the preventive (PM) or corrective maintenance (CM) care and processes for this equipment are still poorly standardized. To describe the maintenance process currently implemented for echocardiographic equipment (ECHO) in a medium-sized laboratory in a tertiary-level public teaching hospital. The description of the process includes damage characterization and MP and MC implementation. Methods: This was a descriptive and exploratory single-center observational study. Data on the maintenance process of echocardiographic equipment were obtained from electronic files from the hospital's equipment management system between 2003 and 2018. Results: Together with the description of the equipment maintenance process, the ten most common types of malfunctions were identified, including software (23.8%), parts (23.1%), and power outage and accessory damage (13.8%). The implementation of the PM process significantly decreased the maintenance costs (USD 44,472.10 vs USD 25,807.59, p = 0.029). Even after the MP, the CM costs related to transesophageal echocardiography equipment (TEE) (USD 7,789.17) were higher than those with other equipment modalities (USD 3,184.37 for transthoracic echocardiography equipment (TTE) and USD 1,813.00 for stress testing). Conclusion: The maintenance process for ECHO equipment was described. ECHO equipment damage has high costs, especially in special modalities such as TEE. PM significantly reduced maintenance costs. (AU)


Assuntos
Humanos , Ecocardiografia/economia , Manutenção de Equipamento/métodos , Análise Custo-Benefício/estatística & dados numéricos , Economia e Organizações de Saúde , Equipamentos e Provisões/economia , Fatores de Tempo , Ecocardiografia Transesofagiana/estatística & dados numéricos , Instituições de Assistência Ambulatorial/organização & administração , Hospitais de Ensino/organização & administração
5.
Can J Cardiol ; 36(12): 1949-1955, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32891729

RESUMO

BACKGROUND: Increased arterial stiffness (AS) has been described as a predictor of atrial fibrillation (AF). This study was performed to assess whether increased AS leads to a higher symptom burden in patients with AF. METHODS: One hundred sixty-two consecutive patients (104 male, 58 female) with diagnosed AF (paroxysmal or persistent) were enrolled. Symptoms most likely attributable to AF were quantified according to the Canadian Cardiovascular Society Severity of Atrial Fibrillation (SAF) scale. AS indices (aortic distensibility, cyclic circumferential strain, and aortic compliance) were characterized using transoesophageal echocardiography. RESULTS: The cohort was divided into asymptomatic to oligosymptomatic (SAF scale 0-1, n = 78 [48.1%]) and symptomatic (SAF scale ≥ 2, n = 84 [51.9%]) patients. Symptomatic patients tended to be younger (median, 75 [interquartile range (IQR) 67-80] vs 71 [65-79]; P = 0.047) and were more likely to be female (22 [28.2%] vs 36 [42.9%]; P = 0.052). Hypertension was more frequent in symptomatic patients. Aortic compliance indices each were reduced in symptomatic patients, most pronounced for aortic compliance (median, 0.05 [IQR 0.03-0.06] vs 0.04 [0.03-0.05] cm/mm Hg; P = 0.01) followed by cyclic circumferential strain (median, 0.09 [IQR 0.07-0.11] vs 0.07 [0.04-0.10]; P = 0.02) and aortic distensibility (10-3 mm Hg-1, median, 1.74 [IQR 1.34-2.24] vs 1.54 [1.12-2.08]; P = 0.03). Multivariable analysis revealed aortic compliance as an independent predictor for symptoms in patients with AF with an odds ratio of 2.6 (95% confidence interval, 1.2-3.4; P = 0.003). CONCLUSIONS: AS contributes to a high symptom burden in patients with AF, emphasizing the prognostic role of AS in the early detection and prevention in patients with AF.


Assuntos
Aorta Torácica , Fibrilação Atrial , Hipertensão , Avaliação de Sintomas , Rigidez Vascular , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aorta Torácica/fisiopatologia , Doenças Assintomáticas/epidemiologia , Doenças Assintomáticas/terapia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/prevenção & controle , Diagnóstico Precoce , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Alemanha/epidemiologia , Humanos , Hipertensão/diagnóstico , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Serviços Preventivos de Saúde , Prognóstico , Índice de Gravidade de Doença , Avaliação de Sintomas/métodos , Avaliação de Sintomas/estatística & dados numéricos
6.
Comput Math Methods Med ; 2020: 4942121, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32802148

RESUMO

Transesophageal echocardiography (TEE) has become an essential tool in interventional cardiologist's daily toolbox which allows a continuous visualization of the movement of the visceral organ without trauma and the observation of the heartbeat in real time, due to the sensor's location at the esophagus directly behind the heart and it becomes useful for navigation during the surgery. However, TEE images provide very limited data on clear anatomically cardiac structures. Instead, computed tomography (CT) images can provide anatomical information of cardiac structures, which can be used as guidance to interpret TEE images. In this paper, we will focus on how to transfer the anatomical information from CT images to TEE images via registration, which is quite challenging but significant to physicians and clinicians due to the extreme morphological deformation and different appearance between CT and TEE images of the same person. In this paper, we proposed a learning-based method to register cardiac CT images to TEE images. In the proposed method, to reduce the deformation between two images, we introduce the Cycle Generative Adversarial Network (CycleGAN) into our method simulating TEE-like images from CT images to reduce their appearance gap. Then, we perform nongrid registration to align TEE-like images with TEE images. The experimental results on both children' and adults' CT and TEE images show that our proposed method outperforms other compared methods. It is quite noted that reducing the appearance gap between CT and TEE images can benefit physicians and clinicians to get the anatomical information of ROIs in TEE images during the cardiac surgical operation.


Assuntos
Ecocardiografia Transesofagiana/estatística & dados numéricos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Cirurgia Assistida por Computador/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Adulto , Bases de Dados Factuais/estatística & dados numéricos , Humanos , Interpretação de Imagem Assistida por Computador/estatística & dados numéricos , Imagem Multimodal/estatística & dados numéricos , Redes Neurais de Computação
7.
Pediatr Cardiol ; 41(7): 1370-1375, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32488509

RESUMO

3D transesophageal echocardiography (3D-TEE) has proven useful and accurate during some operating room (OR), interventional cardiac catheterization (Cath), and electrophysiologic (EP) procedures. The use of 3D-TEE during similar procedures in patients who have undergone Fontan surgery and its additional value have not been previously reported. To determine if live 3D-TEE during procedures post Fontan has added value, 3D-TEEs in 58 post-Fontan patients over a 5-year study period were reviewed. Additional information provided by 3D-TEE (over 2D-TEE) was classified into the following: A: new information which changed/refined the plan and 0: no new important information. Pre- and post-bypass OR 3D-TEEs were counted as one study. A total of 67 3D-TEEs (41 Cath, 13 OR, and 13 EP procedures) were performed. Median age was 14 years (6-39 years). Median weight was 47 kg (21-109 kg). In Cath procedures, only 2/41 (5%) were graded A (R to L atrial level shunt [Fontan leak], n = 1; thrombus in pulmonary artery stump, n = 1). In the OR, 6/13 (46%) were graded A (atrioventricular valvuloplasty, n = 1; neo-aortic valvuloplasty, n = 1; relief of systemic and pulmonary venous outflow obstruction, n = 2 and n = 2; respectively). In EP procedures, 4/13 (31%) were graded A (thrombus, n = 3; mapping for lead placement to assist in multisite pacing for dyssynchrony, n = 1). 3D-TEE of Fontan improved visualization and frequently added value in the OR/EP lab and may be helpful in select catheterization cases. Future studies with a larger sample could build on this data to identify when 3D-TEE will be most useful.


Assuntos
Ecocardiografia Tridimensional/estatística & dados numéricos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Adolescente , Adulto , Cateterismo Cardíaco/métodos , Criança , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Masculino , Trombose/fisiopatologia , Adulto Jovem
8.
J Am Soc Echocardiogr ; 33(6): 658-665, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32503702
9.
Am J Cardiol ; 125(8): 1209-1215, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32087996

RESUMO

New-generation devices such as Evolut and Portico have provided favorable results in patients who underwent transcatheter aortic valve implantation (TAVI) for aortic stenosis, but their comparative effectiveness remains debated, despite its relevance when envisioning TAVI in low-risk patients. We evaluated the safety and efficacy of 2 leading TAVI devices (Evolut and Portico) used by the same team of experienced TAVI operators, focusing on long-term outcomes, including major adverse events (i.e., the composite of death, stroke, myocardial infarction, major vascular complication, or major bleeding). Unadjusted and propensity score-adjusted analyses were carried out. A total of 233 patients were included, 119 (51.1%) receiving Evolut and 114 (49%) Portico. Baseline and procedural data showed significant between-device differences, including functional class, surgical risk, chronic obstructive pulmonary disease, renal function, transesophageal guidance, device size, postdilation, and procedural time (all p <0.05). Yet, acute and in-hospital outcomes were not significantly different (all p >0.05). Follow-up status was ascertained in 228 (98%) patients after 15.0 ± 7.6 months. Unadjusted analysis showed similar rates of major adverse events, as well as the individual risk of death, stroke, myocardial infarction, major vascular complication, major bleeding, and pacemaker implantation (all p >0.05). Even at propensity score-adjusted analysis outcomes were not significantly different with Evolut and Portico (all p >0.05). In conclusion, Evolut and Portico devices yield similarly favorable results at long-term follow-up when used by experienced TAVI operators.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Comorbidade , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Seguimentos , Hemorragia/epidemiologia , Humanos , Masculino , Mortalidade , Infarto do Miocárdio/epidemiologia , Duração da Cirurgia , Pontuação de Propensão , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Insuficiência Renal/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Cirurgia Assistida por Computador , Substituição da Valva Aórtica Transcateter/métodos
10.
Anaesthesia ; 75(1): 21-26, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31236918

RESUMO

Previous studies on the safety of peri-operative transoesophageal echocardiography seem to suggest a low rate of associated morbidity and mortality. That said, there has been a paucity of prospective multicentre studies in this important area of clinical practice. We carried out a one-year prospective study in 2017, co-ordinated by the Association of Cardiothoracic Anaesthesia and Critical Care, to determine the rate and severity of complications associated with peri-operative transoesophageal echocardiography in anaesthetised cardiology and cardiac surgical patients. With the help of clinicians from 28 centres across the UK and Ireland, we recorded the total number of examinations conducted in anaesthetised patients during the study period. All major complications at each centre were prospectively reported and recorded. Of the 22,314 examinations, there were 17 patients diagnosed with a major complication which caused either palatal injury or gastro-oesophageal disruption. This corresponds to an incidence of 0.08% (95%CI 0.05-0.13%) or approximately 1:1300 examinations. There were seven deaths reported during the study period which were directly attributed to these complications, corresponding to an incidence of 0.03% (95%CI 0.01-0.07%) or approximately 1:3000. These figures are higher than previously reported and suggest a high probability of death following the development of a complication (~40%). Most complications occurred in patients without known risk factors for transoesophageal echocardiography associated gastro-oesophageal injury. We suggest clinicians and departments review their procedural guidelines, especially in relation to probe insertion techniques, together with the information communicated to patients when the risks and benefits of such examinations are discussed.


Assuntos
Anestesia em Procedimentos Cardíacos , Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Transesofagiana/efeitos adversos , Auditoria Médica/estatística & dados numéricos , Assistência Perioperatória/efeitos adversos , Idoso , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Humanos , Irlanda , Masculino , Assistência Perioperatória/métodos , Assistência Perioperatória/estatística & dados numéricos , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Sociedades Médicas , Reino Unido
11.
J Intensive Care Med ; 35(9): 896-902, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30189783

RESUMO

OBJECTIVE: Critical care echocardiography has become an integral tool in the assessment and management of critically ill patients. Critical care transesophageal echocardiography (TEE) offers diagnostic reliability, superior image quality, and an expanded diagnostic scope to transthoracic echocardiography. Despite its favorable attributes, TEE use in North American intensive care units (ICUs) remains relatively undescribed. In this article, we seek to characterize the feasibility, indications, and clinical impact of a critical care TEE program. DESIGN: Retrospective, observational study. SETTING: Tertiary care, academic critical care program consisting of 2 hospitals in Ontario, Canada. PARTICIPANTS: Consecutive critical care TEE examinations on ICU patients performed between December 2012 and December 2016. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Consecutive critical care TEE studies on ICU patients from December 1, 2012, to December 31, 2016, were reviewed. The TEEs performed on cardiac surgery patients and those without reports were excluded. Examination details, including indications, complications, examination complexity (number of views, Doppler techniques), and clinical recommendations were aggregated and analyzed. Two hundred seventy-four TEE studies were performed by 38 operators. Common indications for TEE studies were hemodynamic instability (45.2%), assessment for infective endocarditis (22.2%), and cardiac arrest (20.1%). A change in patient management was proposed following 79.5% of TEE studies. Thirty-eight percent of TEE studies were performed during evening hours or on weekends. There were no mechanical complications. CONCLUSIONS: Our observational data support intensivist-performed TEE as being safe and therapeutically influential across a broad range of indications. Our program's demonstrated feasibility and impact may act as a model for TEE adoption in other North American ICUs.


Assuntos
Cuidados Críticos/métodos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Utilização de Instalações e Serviços/estatística & dados numéricos , Unidades de Terapia Intensiva/estatística & dados numéricos , Idoso , Resultados de Cuidados Críticos , Estado Terminal/terapia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Estudos Retrospectivos
12.
J Am Soc Echocardiogr ; 32(12): 1551-1557.e1, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31679901

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) remains the preferred test to rule out infective endocarditis (IE) but is resource intensive and carries risk. Multiple studies report low sensitivity of transthoracic echocardiography (TTE) for detection of IE; however, these studies did not account for TTE quality. We test the validity of a simple valve visualization grading tool to stratify TTEs by quality and determine whether a high-quality TTE may be used to exclude valvular vegetation and forgo the need for TEE. METHODS: The Valve Visualization on Echocardiography Grade (VEG) tool scores the TTE from 0 to 10 based on leaflet visualization and valve leaflet clarity. The tool was retrospectively applied to 309 sequential patients who underwent both TTE and TEE at an academic teaching hospital between 2011 and 2015. The TEE report was the gold standard for presence or absence of vegetation. Patients with prosthetic valves and pacemaker wires were excluded. Sensitivity of TTE for detecting vegetation was calculated at each VEG score, and the optimal cutoff was identified. RESULTS: A total of 309 patients were included in the analysis. Among the 216 negative TTEs, 19 (9%) had a positive TEE. The median VEG score was 4. A VEG score cutoff >6 provided optimal sensitivity and was used as the cutoff. Overall, 75 (25%) patients had a VEG score >6, and 234 (75%) had a score ≤6. Sensitivity and negative predictive value for IE were higher in the VEG >6 versus VEG ≤6 group (sensitivity 96% vs 66%, negative predictive value 97.5% vs 90%; P < .05). The false-negative rate was lower (2.5% vs 10%; P = .04) in VEG > 6 versus VEG ≤ 6 groups, respectively. CONCLUSIONS: Leaflet visualization and valve leaflet clarity are important components in the TTE evaluation of patients with suspected IE. This study demonstrates that the better the valve leaflets are visualized on TTE (as represented in this population by a score >6), the higher the confidence one can have that the TTE will not be falsely negative for vegetation(s) when vegetation(s) are not noted on these TTEs. If validated in future prospective studies, this may reduce the need to perform an invasive TEE in selected patients undergoing evaluation for native valve IE.


Assuntos
Ecocardiografia Transesofagiana/estatística & dados numéricos , Endocardite/diagnóstico por imagem , Endocardite/microbiologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Adulto , Idoso , Estudos de Coortes , Ecocardiografia/estatística & dados numéricos , Feminino , Doenças das Valvas Cardíacas/microbiologia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
13.
Kardiol Pol ; 77(5): 561-567, 2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-31066721

RESUMO

BACKGROUND: The rate of cardiac device-related infective endocarditis (CDRIE) is increasing worldwide, but no detailed data are available for Poland. AIMS: We aimed to evaluate clinical, diagnostic, and therapeutic data of patients hospitalized due to CDRIE in 22 Polish referential cardiology centers from May 1, 2016 to May 1, 2017. METHODS: Participating cardiology departments were asked to fill in a questionnaire that included data on the number of hospitalized patients, number and types of implanted cardiac electrotherapy devices, and number of infective endocarditis cases. We also collected clinical data and data regarding the management of patients with CDRIE. RESULTS: Overall, 99 621 hospitalizations were reported. Infective endocarditis unrelated to cardiac device was the cause of 596 admissions (0.6%), and CDRIE, of 195 (0.2%). Pacemaker was implanted in 91 patients with CDRIE (47%); cardioverter­defibrillator, in 51 (26%); cardiac resynchronization therapy­defibrillator, in 48 (25%); and cardiac resynchronization therapy­pacemaker, in 5 (2.5%). The most common symptoms were malaise (62%), fever/chills (61%), cough (21%), chest pain (19.5%), and inflammation of the device pocket (5.6%). Cultures were positive in 77.5% of patients. The cardiac device was removed in 91% of patients. The percutaneous approach was most common for cardiac device removal. All patients received antibiotic therapy, and 3 patients underwent a heart valve procedure. Transesophageal echocardiography was performed in 80% of patients. The most common complication was heart failure (25% of patients). CONCLUSIONS: The clinical profile, pathogen types, and management strategies in Polish patients with CDRIE are consistent with similar data from other European countries. Transesophageal echocardiography was performed less frequently than recommended. The removal rate in the Polish population is consistent with the general rates observed for interventional treatment in patients with CDRIE.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/estatística & dados numéricos , Endocardite/etiologia , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Serviço Hospitalar de Cardiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Endocardite/diagnóstico por imagem , Endocardite/epidemiologia , Endocardite/cirurgia , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/estatística & dados numéricos , Polônia/epidemiologia , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/cirurgia
14.
Infection ; 47(1): 45-50, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30178077

RESUMO

OBJECTIVES: Enterococcal bacteremia can be complicated by infective endocarditis (IE) and when suspected, transesophageal echocardiography (TEE) should be performed. The previously published NOVA score can identify patients with enterococcal bacteremia at risk for IE and we aimed to improve the score. METHODS: Factors associated with IE were studied retrospectively in a population-based cohort of patients with monomicrobial Enterococcus faecalis bacteremia (MEFsB). Factors associated with IE in multivariable analysis were included in a new score system which was compared to the NOVA score and validated in a cohort of patients with MEFsB from another region. RESULTS: Among 397 episodes of MEFsB, 44 episodes with IE were compared to those without IE. Long Duration of symptoms (≥ 7 days) and Embolization were associated with IE in the multivariate analysis and hence were added to the NOVA variables (Number of positive cultures, Origin of infection unknown, Valve disease, and Auscultation of murmur) to generate a novel score; DENOVA. The area under the curve in ROC analyses was higher for DENOVA (0.95) compared to NOVA (0.91) (p = 0.001). With a cutoff at ≥ 3 positive variables the DENOVA score has a sensitivity of 100% and specificity of 83% which is superior to the NOVA score (specificity 29%). The DENOVA score was applied to the validation cohort (26 IE episodes and 256 non-IE episodes) and the resulting sensitivity was 100% and the specificity was 85% compared to 35% for NOVA. CONCLUSIONS: The DENOVA score is a useful tool to identify patients with MEFsB where TEE is not needed.


Assuntos
Bacteriemia/complicações , Ecocardiografia Transesofagiana/estatística & dados numéricos , Endocardite Bacteriana/diagnóstico , Enterococcus faecalis/isolamento & purificação , Índice de Gravidade de Doença , Idoso , Idoso de 80 Anos ou mais , Bacteriemia/epidemiologia , Estudos de Coortes , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/microbiologia , Feminino , Infecções por Bactérias Gram-Positivas/diagnóstico por imagem , Infecções por Bactérias Gram-Positivas/epidemiologia , Infecções por Bactérias Gram-Positivas/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Suécia
15.
Echocardiography ; 36(1): 15-21, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30450684

RESUMO

INTRODUCTION: The aim of this study was to evaluate appropriateness of transesophageal echocardiography (TEE) studies based on 2011 Appropriate Use Criteria (AUC) for Echocardiography and its impact on patient management. METHODS AND RESULTS: In a retrospective analysis of 100 inpatient TEEs, 85% of the TEEs ordered were determined to be appropriate, 9% were inappropriate, and 6% were uncertain. Inter-observer differences in the determination of AUC were seen in 24% of the studies, requiring a senior-level cardiologist to make the final determination of AUC score. The variance in interpretation by experts is concerning for how that might translate into differences in clinical practice. Of all TEEs, only 63% led to an active change in care, including changes in medications or procedures, while 37% did not. We found a statistically significant difference between cardiologists' and non-cardiologists' orders for TEE having an impact on patient's clinical care (41% vs 22%, respectively, P < 0.05) (Table ). While not statistically significant, a trend toward clinical change was observed in the appropriate vs inappropriate TEEs (70% vs 44%, respectively, P = 0.06). CONCLUSION: Ideally, the role of a diagnostic cardiovascular imaging test, such as a TEE, is to influence clinical care, if it is ordered appropriately on the right patient. While the AUC guides clinicians on the appropriate use of cardiovascular imaging, it is broadly written and offers room for interpretation to encompass variety of clinical scenarios. Clinical care paths that utilize AUC and standardize use of multidisciplinary institutional resources offer opportunity for optimal clinical impact and patient care.


Assuntos
Ecocardiografia Transesofagiana/estatística & dados numéricos , Fidelidade a Diretrizes/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
16.
Rev Port Cardiol (Engl Ed) ; 37(9): 763-772, 2018 Sep.
Artigo em Inglês, Português | MEDLINE | ID: mdl-30219202

RESUMO

INTRODUCTION: Percutaneous closure of the left atrial appendage (LAA) is a promising therapy in patients with atrial fibrillation with high risk for stroke and contraindication for oral anticoagulation (OAC). Intracardiac echocardiography (ICE) may make this percutaneous procedure feasible in patients in whom transesophageal echocardiography (TEE) is inadvisable. Our aim was to assess the efficacy and safety of LAA closure and the feasibility of ICE compared to TEE to guide the procedure. METHODS: In this cohort study of patients who underwent LAA closure between May 2010 and January 2017, clinical and imaging assessment was performed before and after the procedure. RESULTS: In 82 patients (mean age 74±8 years, 64.4% male) the contraindications for OAC were severe bleeding or anemia (65%), high bleeding risk (14%), labile INR (16%), or recurrent embolic events (5%). The procedural success rate was 96.3%. The procedure was guided by TEE or ICE, and no statistically significant differences were observed between the two techniques. During follow-up, one patient had an ischemic stroke at 12 months, two had bleeding complications at six months, and there were four non-cardiovascular deaths. Embolic and bleeding events were less frequent than expected from the observed CHA2DS2VASc (0.6% vs. 6.3%; p<0.001) and HAS-BLED (1.2% vs. 4.1%; p<0.001) risk scores. CONCLUSIONS: In this population percutaneous LAA closure was shown to be safe and effective given the lower frequency of events than estimated by the CHA2DS2VASc and HAS-BLED scores. The clinical and imaging results of procedures guided by ICE in the left atrium were not inferior to those guided by TEE.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia , Ultrassonografia de Intervenção , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Estudos de Coortes , Ecocardiografia/efeitos adversos , Ecocardiografia/métodos , Ecocardiografia/estatística & dados numéricos , Ecocardiografia Transesofagiana/efeitos adversos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Complicações Pós-Operatórias , Acidente Vascular Cerebral , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos
17.
Curr Med Res Opin ; 34(11): 1907-1912, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29546781

RESUMO

OBJECTIVE: Aortic dissection is an uncommon and potentially fatal complication of pregnancy; however, the association of the number of pregnancies with the indexed and absolute size of the ascending aorta in patients without aortic aneurysm or connective tissue disorders is not well elucidated. RESEARCH DESIGN AND METHODS: In this prospective observational study, women aged 18-80 years old undergoing transesophageal echocardiography in a university-affiliated echocardiography laboratory between 1 January 2015 and 1 September 2015 were enrolled. Indexed and absolute sizes of ascending aorta at the levels of annulus, root, sinotubular junction (STJ), proximal and arch were measured. Patients were grouped according to their gravida number into three classes (class I: ≤3, class II: 4-7, class III: ≥7). RESULTS: Of 653 screened patients, 437 women were included (38.9% gravida class I, 44.3% gravida class II and 16.7% gravida class III). In univariate analysis, the number of pregnancies correlated with indexed diameters of the root (p < .001), STJ (p < .001) and the proximal ascending aorta (p < .001). Meanwhile, the number of pregnancies neither correlated with the annular diameter nor with the arch (p = .070 and p = .154, respectively). In multivariate analyses, the gravida class was among the independent predictors of the root size along with age, aortic insufficiency and the presence of congestive heart failure. CONCLUSION: Gravida class was an independent predictor of aortic size at levels of the root, STJ and the proximal ascending aorta. The largest increase was observed at the level of the aortic root.


Assuntos
Aorta , Ecocardiografia Transesofagiana , Paridade/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Aorta/patologia , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Humanos , Pessoa de Meia-Idade , Análise Multivariada , Tamanho do Órgão , Gravidez , Estudos Prospectivos , História Reprodutiva , Estados Unidos
18.
J Cardiothorac Vasc Anesth ; 32(2): 771-778, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29310938

RESUMO

OBJECTIVE: Patients undergoing pulmonary endarterectomy (PEA) have impaired right ventricular function. The authors sought to assess the clinical utility of commonly used perioperative echocardiographic and right heart catheter measurements in patients undergoing PEA. DESIGN: A single-center prospective observational study. SETTING: The study was conducted in a quaternary care cardiac surgical center in the United Kingdom. PARTICIPANTS: Patients undergoing PEA between April 2015 and January 2016. INTERVENTIONS: Thermodilution cardiac index and echocardiography variables were measured at 3 time points: before sternotomy (T1), after pericardial incision (T2), and after sternal closure (T3). Six-month follow-up echocardiography and 6-minute walk (6-MWT) test were performed. MEASUREMENTS AND MAIN RESULTS: Fifty patients were recruited and complete data sets were available for 41 patients. Tricuspid annular plane systolic excursion declined after pericardial incision and cardiopulmonary bypass (T1: 15 ± 4 mm, T2: 13 ± 4 mm, T3: 7 ± 2 mm; p < 0.0001), returning to baseline 6 months postoperatively. Cardiac index (T1: 2.5 ± 0.7 L/min/m2, T2: 2.6 ± 0.6 L/min/m2, T3: 2.3 ± 0.5 L/min/m2; p = 0.07) and right ventricular fractional area change (T1: 36 ± 11%, T2: 40 ± 12%, T3: 40 ± 9%; p = 0.12) were preserved perioperatively. 6-MWT improved from baseline (294 ± 111 m) to follow-up (357 ± 107 m) (p < 0.001). Pulmonary vascular resistance at T3 correlated moderately with follow-up 6-MWT (R = -0.60). CONCLUSIONS: In patients undergoing PEA, invasive measurements and echocardiography assessment of right ventricular function are not interchangeable. Tricuspid annular plane systolic excursion is not a reliable measure of right ventricular function perioperatively. Pulmonary vascular resistance shows moderate correlation with postoperative functional capacity.


Assuntos
Ecocardiografia Transesofagiana/normas , Endarterectomia/normas , Monitorização Intraoperatória/normas , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Função Ventricular Direita/fisiologia , Ecocardiografia Doppler de Pulso/normas , Ecocardiografia Doppler de Pulso/estatística & dados numéricos , Ecocardiografia Doppler de Pulso/tendências , Ecocardiografia Transesofagiana/estatística & dados numéricos , Ecocardiografia Transesofagiana/tendências , Endarterectomia/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/estatística & dados numéricos , Monitorização Intraoperatória/tendências , Estudos Prospectivos , Resistência Vascular/fisiologia
19.
Semin Cardiothorac Vasc Anesth ; 22(2): 137-145, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29303422

RESUMO

STUDY OBJECTIVE: Describe transesophageal echocardiography (TEE) use, preparatory training and opinions about clinical importance, and future training pathways in a sample of liver transplant anesthesiologists. DESIGN: Online survey questionnaire. SETTING: Liver Transplant Centers in the United States. PARTICIPANTS: Director of Liver Transplant Anesthesia or designated alternate respondent. RESULTS: A total of 79 Directors or alternates from 111 (71%) centers were identified. There were 56 responses (71%) representing 433 transplant anesthesiologists who cared for 63.3% of liver transplant cases performed in 2015. Basic TEE certification was reported more frequently (64%) than advanced (53.6%). At least one team member used TEE in over 90% of responding centers. Most respondents (83.9%) agreed TEE provided unique and valuable clinical information but were equally divided about future training pathways (on the job learning vs basic TEE certification). CONCLUSION: TEE use in liver transplantation is growing with a substantial increase in basic TEE certified users. Transplant anesthesiologists support basic certification but an equal number believe there should be more applied training at the site of care.


Assuntos
Anestesiologistas/educação , Ecocardiografia Transesofagiana , Transplante de Fígado , Adulto , Tomada de Decisões , Ecocardiografia Transesofagiana/estatística & dados numéricos , Bolsas de Estudo , Humanos
20.
Anesth Analg ; 126(1): 62-67, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29116970

RESUMO

BACKGROUND: The perioperative assessment of right ventricular (RV) function remains a challenge. Tricuspid annular plane systolic excursion (TAPSE) using M-mode is a widely used measure of RV function. However, accurate alignment of the ultrasound beam with the direction of annular movement can be difficult with transesophageal echocardiography (TEE) to measure TAPSE, precluding effective use of M-mode to measure annular excursion. Tracking of specular reflectors in the myocardium may provide an angle-independent method to assess annular motion with TEE. We hypothesized that TEE speckle tracking of the lateral tricuspid annular motion represents a comparable measurement to the well-validated M-mode TAPSE on transthoracic echocardiogram (TTE), and may be considered as a reasonable alternative to TAPSE. METHODS: This is a prospective, observational cohort study. We included all patients, who were in sinus rhythm, with a preoperative TTE within 3 months of scheduled cardiac surgery that required intraoperative TEE. Tissue motion annular displacements (TMAD) of the lateral (L), septal (S), and midpoint (M) tricuspid annulus were measured (QLAB Cardiac Motion Quantification; Philips Medical, Andover, MA) after induction of general anesthesia. This was compared to the preoperative M-mode TAPSE on TTE. RESULTS: Seventy-two consecutive patients who met eligibility requirements were enrolled from September to November 2016. Twelve were excluded due to poor image quality, allowing TMAD to be analyzed in 60 patients. TMAD was analyzed offline and TMAD analysis was able to track tricuspid annular motion in all patients. The mean TMAD (L), TMAD (S), and TMAD (M) were 17.4 ± 5.2, 10.2 ± 4.8, and 14.2 ± 4.8 mm, respectively. TMAD (L) showed close correlation with M-mode TAPSE on TTE (r = 0.87, 95% confidence interval, 0.79-0.92; P < .01). All patients with a preoperative TAPSE <17 mm had a TMAD (L) <17 mm, while 71% of those with a TAPSE ≥ 17 mm had a TMAD (L) ≥ 17 mm. There was strong positive correlation between TMAD (L) and intraoperative RV fractional area change (r = 0.86, 95% confidence interval, 0.77-0.91; P < .01). Reproducibility analysis of TMAD within and across observers showed excellent correlation. CONCLUSIONS: TMAD is a quick and angle-independent method to quantitatively assess RV longitudinal function by TEE. It correlates strongly with M-mode TAPSE on TTE. Because TMAD and TAPSE were not simultaneously measured in this study, their correlation is subject to differences in loading conditions, general anesthesia, and changes in the disease process. TMAD may be easily applied in routine clinical settings and its role in the perioperative environment deserves to be further explored.


Assuntos
Anestesia Geral , Ecocardiografia Transesofagiana/estatística & dados numéricos , Monitorização Intraoperatória , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiologia , Função Ventricular Direita/fisiologia , Idoso , Anestesia Geral/métodos , Estudos de Coortes , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...